We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Co2 Fire extinguisher Missing Nite-Glo Signs
CO2 Fire Extinguisher Missing Nite-Glo Signs help you show where a carbon dioxide extinguisher belongs, how it should be used and when it is missing. You should use them at fire points, extinguisher stands and electrical-risk areas where quick recognition matters.
Where CO2 Missing Nite-Glo Signs Should Be Installed
You should install this sign directly behind or above the CO₂ extinguisher position, especially on extinguisher stands, fire points, plant rooms, server areas, workshops and corridors. The large missing section helps you spot an empty location during checks or low-light conditions.
Viewing Distance for Clear CO2 Fire Point Recognition
For an 800 x 600mm sign, keep the face clearly visible from typical approach routes of around 20–30 metres. Use closer placement where shelving, machinery, vehicles or corridor turns could block the message.
| Size option | Practical viewing guidance | Best placement |
|---|---|---|
| H 800 x W 600mm | Approx. 20–30 metres where sightlines are open | Fire points, extinguisher stands and larger work areas |
What Improves Once This CO2 Missing Sign Is Fitted
This sign changes behaviour by making the CO₂ location harder to overlook, the missing extinguisher status easier to challenge and the correct use limits clearer before anyone grabs the wrong equipment under pressure.
CO2 Missing Nite-Glo Sign Technical Details
- Purpose: identifies CO₂ extinguisher position and missing status
- Sign message: “Fire extinguisher”
- Sign message: “CO₂ Carbon Dioxide”
- Sign message: “MISSING”
- Use message: “For use on: Flammable liquids”
- Use message: “For use on: Live electrical equipment”
- Restriction message: “Do not use on: Wood, paper and textiles”
- Restriction message: “Do not use on: Flammable metal fires”
- Restriction message: “Do not use in a confined space or hold horn when operating”
- Pictogram symbols: fire extinguisher, flames and CO₂ use icons
- EN ISO 7010 code: F001 fire extinguisher
- EN ISO 7010 code: P011 do not extinguish with water
- Conforms to EN ISO 7010 where standard symbols apply
- Conforms to BS 5499 sign regulations
- Compliant with PSPA, DIN, IMO and British Standard requirements
- Photoluminescence class: PSPA Class B
- Material options: Rigid Plastic or Polyester
- Size: H 800 x W 600mm
- Background colours: red, green and black
- Text colours: white and black
- Symbol colours: white, black and red
- Finish: photoluminescent film glows brightly in darkness
- Illumination: 6hrs+ after charging
- Where to use: indoor and outdoor CO₂ fire points
Fitting Advice for CO2 Missing Fire Extinguisher Locations
❌ Do not fit it where the extinguisher hides the missing message.
❌ Do not place it behind stored goods, doors or machinery.
❌ Do not mount it so high that the use guidance cannot be read.
❌ Do not use it for water, foam or powder extinguisher points.
❌ Do not rely on it as a substitute for extinguisher servicing.
❌ Do not use adhesive polyester on dirty, damp or unstable surfaces.
✅ Install at eye level where the approach route is clear.
✅ Fit one sign per CO₂ extinguisher position or stand.
✅ Check visibility during routine fire equipment inspections.
CO2 Fire Extinguisher Missing Indicator Signs questions answered
What are CO2 Fire Extinguisher Missing Indicator Signs used for? They show where a CO₂ extinguisher should be, explain its correct fire use and make an empty position obvious during checks.
Should I use this sign behind the extinguisher or above it? Fit it where it remains visible when the extinguisher is in place. Behind a stand or directly above the location usually works best.
Why choose a photoluminescent CO₂ missing sign? It helps the fire point remain readable when normal lighting fails, which is useful in corridors, plant rooms and larger work areas.
Is this suitable for electrical-risk locations? Yes, CO₂ extinguishers are commonly used near live electrical equipment, so this sign helps you guide people towards the correct extinguisher type.
When is this CO₂ extinguisher missing sign the right choice? Choose it when you need a large fire point sign that gives use guidance and also flags when the extinguisher has been removed.
CO2 Fire Extinguisher Missing Sign Features and Practical Benefits
- ✓ Large H 800 x W 600mm portrait layout
- ✓ CO₂ use and non-use guidance included
- ✓ Photoluminescent finish for low-light visibility
- ✓ Missing extinguisher section for fire point checks
- ✓ Helps you find empty extinguisher positions quickly
- ✓ Reduces wrong extinguisher selection under pressure
- ✓ Supports safer response near electrical equipment
- ✓ Improves audit control across active work areas
CO₂ missing-equipment sign comparisons
For a broader missing message, compare CO₂ extinguisher missing signs where you want a clear absence warning. Useful when equipment should be returned quickly after inspection or use.
If you are replacing missing signage rather than missing equipment, choose CO₂ ID signs for confirmed extinguisher positions. This keeps the message accurate once the unit is back in place.
For multiple extinguisher points, review portrait CO₂ ID sign packs for site-wide checks. Helpful when several positions need consistent marking after a safety audit.
For the wider choice, browse CO₂ extinguisher signs for audits and replacement planning. It helps you separate missing-equipment warnings from standard location signage.
Estimated Delivery Day
Current date and time:
Estimated delivery by:
Based on an estimated 3 working day delivery timeframe from today, excluding weekends and bank holidays. Delivery dates are provided as a guide only and may vary depending on the product ordered, stock availability at the time of purchase, production or printing lead times.