We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
In The Event Of Fire Do Not Use Lift Acrylic Signs
This clear acrylic “In the event of fire do not use this lift” sign helps you stop people using lifts during a fire. Use it at indoor lift entrances, lift lobbies and reception areas where fast decisions matter and the risk is people heading for the wrong escape option.
Best Places To Fit This Lift Fire Sign
You should install this sign beside lift doors, above call buttons or at eye level in lift lobbies. It needs to be seen before anyone presses for the lift, so the instruction is clear while they still have time to choose stairs or the approved escape route.
Practical Viewing Distance
Choose the size by how far back people first see the lift. Smaller signs suit close decision points; the larger option gives stronger visibility across wider receptions, shared corridors and busier entrance areas.
| Size option | Practical viewing guide | Best fit |
|---|---|---|
| H 210 x W 148 mm | Around 1–4 metres | Single lift doors and close approach points |
| H 297 x W 210 mm | Around 2–6 metres | Lift lobbies, receptions and wider indoor areas |
What Changes After It Is Fitted
This sign gives people a clear instruction before they act, reducing hesitation at lift doors and helping you steer visitors, staff, residents and contractors away from lift use during a fire evacuation.
- Sign message: “In the event of fire do not use this lift”
- Purpose: prohibit lift use during fire
- Where to use: indoor lift areas
- Sign type: prohibition
- EN ISO 7010 code: P020
- Pictogram: lift with occupants and flame
- Prohibition symbol: red circle and diagonal bar
- Conforms to EN ISO 7010
- Conforms to BS 5499 sign regulations
- Material: clear acrylic
- Material thickness: 6mm
- Finish: green edge, high gloss
- Shape: rectangle
- Orientation: portrait
- Background colour: red/white
- Text colour: white
- Symbols colour: red/black
- Size options: H 210 x W 148 mm, H 297 x W 210mm
- Non-Photoluminescent
- Non-reflective
- Supplied in single
- Fitting method: wall mount
- Fixings: 4 x screws and 4 x silver supports included
- Protrudes 20mm from the wall
Installation Guidance
❌ Do not fit it too high above the lift doors where people only see it after pressing the button.
❌ Do not hide it behind plants, furniture, door frames or reception displays.
❌ Do not place it only inside the lift, because the decision has already been made.
❌ Do not rely on this Non-Photoluminescent version in poorly lit areas without suitable lighting.
❌ Do not use it outdoors unless the location is suitably protected and the product suitability has been checked.
❌ Do not use it as a replacement for fire exit signs, evacuation plans or staff training.
✅ Install it at eye level beside the lift entrance or near the call button.
✅ Use the larger size where people approach from across a lobby or reception area.
✅ Check the sign during routine fire safety inspections so it remains clean, secure and visible.
Frequently Asked Questions
Are In The Event Of Fire Do Not Use Lift Acrylic Signs right for reception areas? Yes. The clear acrylic and raised fixing style make them suitable where you need the fire instruction to look professional as well as easy to see.
Should this sign be fitted at every lift? You should fit it where people make the decision to use a lift, especially at main lift entrances, shared lift lobbies and floors used by visitors or contractors.
Is this sign suitable for dark escape routes? This version is Non-Photoluminescent, so it is best used in indoor areas with reliable normal or emergency lighting.
Does the sign tell people which route to use instead? No. It tells people not to use the lift during fire. You should pair it with appropriate fire exit signs and your building’s fire evacuation instructions.
Why choose acrylic rather than a basic flat sign? Acrylic works well where appearance matters, such as offices, hotels, managed residential buildings and public reception areas, while still giving a firm prohibition message.
Features and Benefits
- ✓ Clear acrylic face with green-edge, high-gloss finish
- ✓ Recognisable red prohibition design with lift and fire graphic
- ✓ Raised wall-mounted appearance using supplied supports
- ✓ Portrait layout keeps the instruction compact and direct
- ✓ Helps the sign suit smart reception and front-of-house areas
- ✓ Makes the fire instruction easy to understand under pressure
- ✓ Keeps the message prominent without looking temporary
- ✓ Helps you guide staff, visitors and residents before they reach the lift
Compare related lift fire notices
For a direct fire safety message beside lifts, use in the event of fire do not use this lift signs where people need a clear instruction before deciding to enter. Suitable for lift entrances, landings and shared building areas.
If you are checking several lift warning options, browse the do not use lift in fire sign range to keep wording consistent across your premises. Useful when upgrading fire safety signage across multiple floors.
Estimated Delivery Day
Current date and time:
Estimated delivery by:
Based on an estimated 3 working day delivery timeframe from today, excluding weekends and bank holidays. Delivery dates are provided as a guide only and may vary depending on the product ordered, stock availability at the time of purchase, production or printing lead times.